/*
 * Screen layout only. 1840 px is the actual main content limit:
 * it excludes the navigation rail and both outer page gutters.
 * The original stylesheet continues to control printed output.
 */
@media screen {
  :root {
    --content-width: 1840px;
    --page-gutter: clamp(24px, 2.5vw, 48px);
    --layout-rail: var(--sidebar-width, 256px);
    --frame-max: calc(var(--content-width) + var(--page-gutter) + var(--page-gutter));
  }

  .main {
    box-sizing: border-box;
    width: calc(100% - var(--layout-rail));
    max-width: var(--frame-max);
    margin-inline-start: calc(var(--layout-rail) + max(0px, (100% - var(--layout-rail) - var(--frame-max)) / 2));
    margin-inline-end: 0;
    padding: 112px var(--page-gutter) 72px;
    container-type: inline-size;
    container-name: workspace;
  }

  .main > * { min-width: 0; max-width: 100%; }
  .main :where(.panel, .card, .asset-card, .template-stage, .template-sidebar, .rule-body, .field) { min-width: 0; }
  .main :where(h1, h2, h3, p, label, .btn, .value, .pill) { overflow-wrap: break-word; }
  .card :where(.card-title, .card-description, h2, h3, p, code, a),
  .asset-card :where(h3, p, code, a) { overflow-wrap: anywhere; word-break: normal; }
  .main :where(input, select, textarea) { max-width: 100%; }
  .main .vv-root { width: 100%; max-width: 100%; }

  /* Header and content share exactly the same frame and gutters. */
  .topbar {
    left: var(--layout-rail);
    padding: 0;
    display: block;
    gap: 0;
  }
  .topbar-inner {
    box-sizing: border-box;
    display: flex;
    align-items: center;
    gap: 16px;
    width: 100%;
    max-width: var(--frame-max);
    height: 100%;
    margin-inline: auto;
    padding-inline: var(--page-gutter);
    min-width: 0;
  }
  .topbar-inner > .breadcrumb {
    min-width: 0;
    overflow: hidden;
    text-overflow: ellipsis;
    white-space: nowrap;
  }
  .topbar-inner > .search-trigger {
    flex: 0 1 260px;
    min-width: 176px;
    width: 260px;
    max-width: 320px;
    margin-left: auto;
  }
  .topbar-inner > .top-actions { flex-shrink: 0; }

  .page-head { margin-bottom: 36px; }
  .page-head .lede { max-width: 88ch; }
  .page-head .head-actions { max-width: 100%; }
  .hero { grid-template-columns: minmax(0, 1.14fr) minmax(0, 1fr); min-height: 470px; }
  .hero-copy { padding: clamp(28px, 3cqi, 56px); }
  .hero-copy h2 { max-width: 20ch; margin-bottom: 24px; font-size: clamp(34px, 3cqi, 56px); line-height: 1.28; }
  .hero-copy p { max-width: 66ch; font-size: 16px; }
  .hero-visual { min-height: 420px; padding: clamp(28px, 3cqi, 52px); }
  .hero-visual > img { width: 100%; max-width: 360px; max-height: 360px; }
  .hero-product-ring { max-width: 460px; }
  .hero-product-caption { max-width: 620px; }
  .hero-measure { max-width: 700px; }

  .card-grid, .swatch-grid, .asset-grid {
    grid-template-columns: repeat(3, minmax(0, 1fr));
    gap: 22px;
  }
  .card { padding: 28px; }
  .card-description { max-width: 62ch; }
  .quick-grid { grid-template-columns: repeat(2, minmax(0, 1fr)); gap: 20px; }
  .stat-grid { grid-template-columns: repeat(4, minmax(0, 1fr)); }
  .stat { padding: 24px 28px; }
  .foundation-strip { width: 100%; }
  .color-segment { min-height: 116px; }
  .swatch-color { min-height: 172px; }
  .asset-preview { height: 220px; }
  .asset-preview.template-thumb { height: 250px; }
  .template-thumb img { max-height: 210px; }
  .preset-grid { grid-template-columns: repeat(4, minmax(0, 1fr)); gap: 16px; }
  .two-column { grid-template-columns: repeat(2, minmax(0, 1fr)); gap: 28px; align-items: start; }
  .two-column > .panel { height: 100%; }
  .two-column > .panel > p { max-width: 78ch; }
  .panel .section-title:first-child { margin-top: 0; }

  /* Long reading remains bounded, even when its structural frame is wide. */
  .guide-layout {
    display: grid;
    grid-template-columns: minmax(0, 1fr) 248px;
    align-items: start;
    gap: 28px;
  }
  .guide-layout > .rule-list { display: grid; grid-template-columns: minmax(0, 1fr); width: 100%; }
  .guide-layout > .guide-toc { height: auto; width: 100%; position: sticky; top: 96px; }
  .rule { grid-template-columns: 44px minmax(0, 1fr); align-content: start; }
  .rule-body { max-width: 100%; }
  .rule-body :where(h2, h3, p, .rule-values) { max-width: min(100%, 78ch, 800px); }
  .rule-body p { font-size: 15px; line-height: 1.9; }
  .main > .principle-list li { max-width: 86ch; }
  .check-row > span { max-width: 100ch; }

  /* Real inputs keep an efficient width; the result is the flexible column. */
  .two-column:has(#ai-output) { grid-template-columns: 400px minmax(0, 1fr); }
  .two-column:has(#ai-output) > .export-code { margin-top: 0; }
  .two-column:has(#ai-output) #ai-output { min-height: 680px; font-size: 13px; line-height: 1.85; }
  .two-column:has(#proposal-form) { grid-template-columns: minmax(0, 1fr) minmax(0, 1fr); }
  .version-timeline .timeline-item p { max-width: 78ch; }

  .template-layout { grid-template-columns: 320px minmax(0, 1fr); gap: 28px; }
  .template-sidebar { padding: 26px; }
  .template-stage { width: 100%; }
  .canvas-frame { min-height: 520px; padding: 32px; }
  #template-canvas > svg, .canvas-frame > img {
    display: block;
    width: 100%;
    max-width: 100%;
    height: auto;
    max-height: 760px;
    object-fit: contain;
  }
  .filter-row, .page-actions, .head-actions, .asset-actions { flex-wrap: wrap; }
  .data-table { width: 100%; }
  .export-code :where(textarea, pre) { width: 100%; min-width: 0; }

  /* A chapter-specific application study is a reading-size figure. */
  .panel:has(.asset-preview img[src*="assets/extension/"]) > .asset-grid { grid-template-columns: minmax(0, 1fr); }
  .panel:has(.asset-preview img[src*="assets/extension/"]) .asset-preview { height: auto; min-height: 0; padding: 20px; }
  .panel:has(.asset-preview img[src*="assets/extension/"]) .asset-preview img { width: 100%; max-height: 620px; object-fit: contain; }

  @container workspace (min-width: 1480px) {
    .card-grid, .swatch-grid, .asset-grid { grid-template-columns: repeat(4, minmax(0, 1fr)); gap: 24px; }
    .quick-grid { grid-template-columns: repeat(4, minmax(0, 1fr)); }
    .preset-grid { grid-template-columns: repeat(6, minmax(0, 1fr)); }
    .hero { min-height: 520px; }
    .hero-visual > img { max-width: 420px; max-height: 420px; }
  }

  @container workspace (min-width: 1600px) {
    .guide-layout > .rule-list {
      grid-template-columns: repeat(2, minmax(0, 1fr));
      gap: 18px;
      border: 0;
      background: transparent;
      align-items: stretch;
    }
    .guide-layout .rule {
      grid-template-columns: 34px minmax(0, 1fr);
      gap: 10px;
      padding: 25px;
      border: 1px solid var(--line);
      border-radius: var(--radius);
      background: white;
    }
  }

  @container workspace (max-width: 1119px) {
    .template-layout { grid-template-columns: 288px minmax(0, 1fr); gap: 22px; }
    .template-sidebar { padding: 23px; }
    .guide-layout { grid-template-columns: minmax(0, 1fr) 224px; gap: 22px; }
    .card { padding: 24px; }
    .canvas-frame { padding: 24px; min-height: 440px; }
    .preset-grid { grid-template-columns: repeat(3, minmax(0, 1fr)); }
  }

  @container workspace (max-width: 1039px) {
    .card-grid, .swatch-grid, .asset-grid { grid-template-columns: repeat(2, minmax(0, 1fr)); gap: 18px; }
    .two-column:has(#ai-output) { grid-template-columns: 340px minmax(0, 1fr); gap: 22px; }
    .hero-copy h2 { font-size: 36px; }
    .hero-copy p { font-size: 15px; }
    .hero-visual { padding: 28px; min-height: 370px; }
    .hero-visual > img { max-width: 320px; max-height: 320px; }
    .stat { padding: 22px; }
  }

  @container workspace (max-width: 839px) {
    .hero { grid-template-columns: minmax(0, 1fr); min-height: 0; }
    .hero-copy { padding: 30px; }
    .hero-copy h2 { max-width: 24ch; font-size: 36px; }
    .hero-visual { min-height: 340px; padding: 30px; border-left: 0; border-top: 1px solid var(--line); }
    .hero-visual > img { max-width: 310px; max-height: 310px; }
    .hero-code, .hero-product-caption { max-width: 620px; }
    .hero-code { align-self: center; width: 100%; }
    .two-column, .two-column:has(#ai-output), .two-column:has(#proposal-form) { grid-template-columns: minmax(0, 1fr); }
    .two-column > .panel { height: auto; }
    .two-column:has(#ai-output) #ai-output { min-height: 520px; }
    .guide-layout { display: flex; flex-direction: column; gap: 22px; }
    .guide-layout > .guide-toc { position: static; order: -1; width: 100%; }
    .guide-toc .toc-item { display: block; }
    .template-layout { grid-template-columns: minmax(0, 1fr); }
    .template-sidebar .form-grid { grid-template-columns: repeat(2, minmax(0, 1fr)); }
    .canvas-frame { min-height: 360px; }
    .contrast-results { grid-template-columns: repeat(2, minmax(0, 1fr)); }
  }

  @container workspace (max-width: 639px) {
    .card-grid, .swatch-grid, .asset-grid, .quick-grid { grid-template-columns: minmax(0, 1fr); gap: 16px; }
    .stat-grid { grid-template-columns: repeat(2, minmax(0, 1fr)); }
    .preset-grid { grid-template-columns: repeat(2, minmax(0, 1fr)); }
    .hero-copy { padding: 26px; }
    .hero-copy h2 { font-size: 32px; }
    .rule { grid-template-columns: 28px minmax(0, 1fr); padding: 22px 18px; gap: 10px; }
    .contrast-results { grid-template-columns: minmax(0, 1fr); }
    .hero-measure { gap: 9px 16px; }
  }

  @media (max-width: 1100px) {
    :root { --layout-rail: 0px; }
    .main { width: 100%; margin-inline: auto; }
    .topbar { left: 0; padding: 0; }
  }

  @media (max-width: 760px) {
    :root { --page-gutter: 20px; }
    .main { padding-top: 102px; padding-bottom: 44px; }
    .topbar-inner { gap: 12px; }
    .topbar-inner > .search-trigger { flex: 0 0 42px; width: 42px; min-width: 42px; max-width: 42px; }
    .topbar-inner > .breadcrumb { flex: 1; }
    .topbar-inner > .top-actions { display: none; }
    .page-head { margin-bottom: 28px; }
    .card-grid, .swatch-grid, .asset-grid, .quick-grid { grid-template-columns: minmax(0, 1fr); }
    .preset-grid { grid-template-columns: minmax(0, 1fr); }
    .stat { padding: 18px; }
    .card { padding: 23px; }
    .swatch-color { min-height: 160px; }
    .asset-preview { height: 200px; }
    .asset-preview.template-thumb { height: 230px; }
    .template-thumb img { max-height: 190px; }
    .hero { margin-bottom: 22px; }
    .hero-copy { padding: 28px 24px; }
    .hero-copy h2 { font-size: 30px; }
    .hero-copy p { font-size: 15px; }
    .hero-visual { min-height: 280px; padding: 26px; }
    .hero-visual > img { max-width: 280px; max-height: 280px; }
    .hero-product-ring { max-width: 350px; }
    .hero-code { font-size: 9px; }
    .hero-product-caption { flex-direction: column; gap: 6px; margin-top: 18px; }
    .hero-product-caption b { font-size: 12px; }
    .color-segment { min-height: 100px; }
    .guide-layout { gap: 20px; }
    .rule-body p { font-size: 14px; }
    .rule-body :where(h2, h3, p, .rule-values) { max-width: 100%; }
    .template-layout { gap: 20px; }
    .template-sidebar { padding: 22px; }
    .canvas-frame { min-height: 0; padding: 12px; }
    #template-canvas > svg, .canvas-frame > img { width: 100%; max-width: 100%; height: auto; max-height: none; }
    .canvas-meta { gap: 6px 14px; }
    .two-column:has(#ai-output) #ai-output { min-height: 460px; font-size: 12px; }
    .panel:has(.asset-preview img[src*="assets/extension/"]) .asset-preview { padding: 8px; }
    .panel:has(.asset-preview img[src*="assets/extension/"]) .asset-preview img { max-height: none; }
  }

  @media (max-width: 359px) {
    :root { --page-gutter: 16px; }
    .topbar-inner { gap: 9px; }
    .hero-copy { padding: 24px 20px; }
    .hero-copy h2 { font-size: 28px; }
    .hero-visual { padding: 22px; }
    .hero-visual > img { max-width: 240px; max-height: 240px; }
    .hero-measure { font-size: 8px; letter-spacing: .02em; }
    .template-sidebar { padding: 18px; }
    .logo-preview:has(.logo-safe-frame) { padding-inline: 12px; }
    .logo-safe-frame { padding: 18px 16px; min-height: 124px; }
  }
}
